F1-F10 = Function Keys
Orange+F5=on screen keyboard
Orange+F10 toggles menu to exit Velocity, end session, etc.
TAB
Power
SCAN
Backspace
5. ENTER
6. Orange+E = F6
7. Orange+F = F7
Granit 1980i RS232 Scanner Configuration Specific for JDA/WMS on the Honeywell VM1A fork truck computer
No Prefix, Center Decode, Enable All, Tab Suffix
Granit 1991i XR Bluetooth Scanner Configuration Specific for JDA/WMS on the Honeywell VM1A fork truck computer
No Prefix, Center Decode, Enable All, Tab Suffix
Zebra DS3608 RS232 Scanner Configuration Specific for JDA/WMS on the Honeywell VM1A fork truck computer
No Prefix, Picklist, Enable All, Intercharacter Delay, Level 2 Security, Tab Suffix
Each Device Uses A Specific Screen Size Per Device & Unique Terminal ID (set in JDA maintenance module). This is provided by the HCL Run team for JDA.
- Fork Truck Screen Size: 8x40 (landscape)
- Handheld Screen Size: 16x20 (portrait)
- Wearable Screen Size: 16x20 (landscape)
^Enter Site Specific Terminal ID Value^
Password To Change Terminal ID/Answerback/Device ID
Password is "system"
Correct JDA Layout & Answerback
RECONNECTING (WON'T CONNECT)
- Host Address is incorrect
- Host Address is incomplete (add in .company.xyz.com)
- DNS name won't resolve (try IP address)
- Incorrect Port Number (try to connect from telnet on PC, Putty, etc.)
Incorrect JDA Layout
Mismatched Screen Size or Device type (vehicle/handheld) in WMS Configuration Setup
mismatched Answerback/Device ID/Terminal ID
Velocity version needs to be 2.1.29+
AbeTech 12560 Fletcher Lane Suite 100 Rogers MN 55374 http://www.abetech.com Ph. 800-478-8644 Driven By COS